S390L Firefly + D130 Dry Eye Diagnostic System
Evaluate the ocular surface with the MediWorks S390L Firefly + D130, featuring non-invasive dry-eye tests, digital slit-lamp imaging and DICOM.
The MediWorks S390L Firefly + D130 combines a high-resolution digital slit lamp with specialized dry-eye analysis capabilities. Its guided workflow supports comprehensive ocular-surface examinations and generates quantitative information to assist qualified professionals with diagnosis, documentation and patient follow-up.
The system supports non-invasive tear meniscus height and tear-film breakup time assessment, meibomian gland evaluation, lipid-layer observation, eyelid-margin examination, blink analysis and conjunctival hyperemia assessment. It also facilitates fluorescein breakup-time evaluation and corneal fluorescein staining documentation.
Its fully automatic Firefly digital module simplifies image acquisition without requiring routine camera-parameter adjustments. A 12-megapixel sensor captures photographs at up to 4056 × 3040 pixels, while video can be recorded at 2592 × 1944 pixels and 30 fps.
High-quality optics, cobalt-blue illumination and a built-in yellow filter improve the visualization of fluorescein patterns, supporting anterior-segment photography and contact or orthokeratology lens fitting. The patient-management system supports record organization, image storage and DICOM integration.
Key Features
- Guided dry-eye examination workflow
- Non-invasive and quantitative evaluation
- Comprehensive dry-eye assessment report
- High-resolution anterior-segment photography
- Automatic exposure and simplified image acquisition
- Five-step magnification from 6.3× to 40×
- 12-megapixel digital image sensor
- Built-in yellow and cobalt-blue filters
- Infrared illumination for meibomian gland imaging
- Real-time video capture and storage
- Contact and orthokeratology lens-fitting support
- Patient record and image-management software
- DICOM support for clinical integration
- Suitable for telemedicine and patient education
Examination Functions
- Dry-eye questionnaires: OSDI, McMonnies, SPEED and DEQ-5
- Non-invasive tear meniscus height
- Non-invasive breakup time—NIBUT
- Fluorescein breakup time
- Meibomian gland function and loss evaluation
- Lipid-layer thickness assessment
- Eyelid-margin examination
- Conjunctival hyperemia analysis
- Blink-quality analysis
- Corneal fluorescein staining
- Comprehensive dry-eye report
| SKU | S390L-D130 |
|---|---|
| Brand | MediWorks |
| Category | Dry Eye Analyzers |